Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
J Biophotonics ; 16(7): e202200166, 2023 07.
Article in English | MEDLINE | ID: covidwho-2265562

ABSTRACT

The development of fast, cheap and reliable methods to determine seroconversion against infectious agents is of great practical importance. In the context of the COVID-19 pandemic, an important issue is to study the rate of formation of the immune layer in the population of different regions, as well as the study of the formation of post-vaccination immunity in individuals after vaccination. Currently, the main method for this kind of research is enzyme immunoassay (ELISA, enzyme-linked immunosorbent assay). This technique is sufficiently sensitive and specific, but it requires significant time and material costs. We investigated the applicability of attenuated total reflection (ATR) Fourier transform infrared (FTIR) spectroscopy associated with machine learning in blood plasma to detect seroconversion against SARS-CoV-2. The study included samples of 60 patients. Clear spectral differences in plasma samples from recovered COVID-19 patients and conditionally healthy donors were identified using multivariate and statistical analysis. The results showed that ATR-FTIR spectroscopy, combined with principal components analysis (PCA) and linear discriminant analysis (LDA) or artificial neural network (ANN), made it possible to efficiently identify specimens from recovered COVID-19 patients. We built classification models based on PCA associated with LDA and ANN. Our analysis led to 87% accuracy for PCA-LDA model and 91% accuracy for ANN, respectively. Based on this proof-of-concept study, we believe this method could offer a simple, label-free, cost-effective tool for detecting seroconversion against SARS-CoV-2. This approach could be used as an alternative to ELISA.


Subject(s)
COVID-19 , Pandemics , Humans , Spectroscopy, Fourier Transform Infrared/methods , COVID-19/diagnosis , SARS-CoV-2 , Discriminant Analysis , Principal Component Analysis , Ataxia Telangiectasia Mutated Proteins
2.
Sci Rep ; 12(1): 20358, 2022 Nov 27.
Article in English | MEDLINE | ID: covidwho-2133638

ABSTRACT

Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy coupled with machine learning-based partial least squares discriminant analysis (PLS-DA) was applied to study if severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) could be detected from nasopharyngeal swab samples originally collected for polymerase chain reaction (PCR) analysis. Our retrospective study included 558 positive and 558 negative samples collected from Northern Finland. Overall, we found moderate diagnostic performance for ATR-FTIR when PCR analysis was used as the gold standard: the average area under the receiver operating characteristics curve (AUROC) was 0.67-0.68 (min. 0.65, max. 0.69) with 20, 10 and 5 k-fold cross validations. Mean accuracy, sensitivity and specificity was 0.62-0.63 (min. 0.60, max. 0.65), 0.61 (min. 0.58, max. 0.65) and 0.64 (min. 0.59, max. 0.67) with 20, 10 and 5 k-fold cross validations. As a conclusion, our study with relatively large sample set clearly indicate that measured ATR-FTIR spectrum contains specific information for SARS-CoV-2 infection (P < 0.001 for AUROC in label permutation test). However, the diagnostic performance of ATR-FTIR remained only moderate, potentially due to low concentration of viral particles in the transport medium. Further studies are needed before ATR-FTIR can be recommended for fast screening of SARS-CoV-2 from nasopharyngeal swab samples.


Subject(s)
COVID-19 , Humans , Spectroscopy, Fourier Transform Infrared/methods , COVID-19/diagnosis , SARS-CoV-2 , Retrospective Studies , Nasopharynx
3.
Anal Chem ; 94(40): 13810-13819, 2022 10 11.
Article in English | MEDLINE | ID: covidwho-2050235

ABSTRACT

Since the outbreak of coronavirus disease 2019 (COVID-19), the epidemic has been spreading around the world for more than 2 years. Rapid, safe, and on-site detection methods of COVID-19 are in urgent demand for the control of the epidemic. Here, we established an integrated system, which incorporates a machine-learning-based Fourier transform infrared spectroscopy technique for rapid COVID-19 screening and air-plasma-based disinfection modules to prevent potential secondary infections. A partial least-squares discrimination analysis and a convolutional neural network model were built using the collected infrared spectral dataset containing 857 training serum samples. Furthermore, the sensitivity, specificity, and prediction accuracy could all reach over 94% from the results of the field test regarding 968 blind testing samples. Additionally, the disinfection modules achieved an inactivation efficiency of 99.9% for surface and airborne tested bacteria. The proposed system is conducive and promising for point-of-care and on-site COVID-19 screening in the mass population.


Subject(s)
COVID-19 , COVID-19/diagnosis , Humans , Least-Squares Analysis , Neural Networks, Computer , Spectroscopy, Fourier Transform Infrared/methods
4.
Spectrochim Acta A Mol Biomol Spectrosc ; 285: 121883, 2023 Jan 15.
Article in English | MEDLINE | ID: covidwho-2031671

ABSTRACT

Alternative routes such as virus transmission or cross-contamination by food have been suggested, due to reported cases of SARS-CoV-2 in frozen chicken wings and fish or seafood. Delay in routine testing due to the dependence on the PCR technique as the standard method leads to greater virus dissemination. Therefore, alternative detection methods such as FTIR spectroscopy emerge as an option. Here, we demonstrate a fast (3 min), simple and reagent-free methodology using attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy for discrimination of food (chicken, beef and fish) contaminated with the SARS-CoV-2 virus. From the IR spectra of the samples, the "bio-fingerprint" (800 - 1900 cm-1) was selected to investigate the distinctions caused by the virus contamination. Exploratory analysis of the spectra, using Principal Component of Analysis (PCA), indicated the differentiation in the data due to the presence of single bands, marked as contamination from nucleic acids including viral RNA. Furthermore, the partial least squares discriminant analysis (PLS-DA) classification model allowed for discrimination of each matrix in its pure form and its contaminated counterpart with sensitivity, specificity and accuracy of 100 %. Therefore, this study indicates that the use of ATR-FTIR can offer a fast and low cost and not require chemical reagents and with minimal sample preparation to detect the SARS-CoV-2 virus in food matrices, ensuring food safety and non-dissemination by consumers.


Subject(s)
COVID-19 , SARS-CoV-2 , Cattle , Animals , Spectroscopy, Fourier Transform Infrared/methods , Chemometrics , COVID-19/diagnosis , Discriminant Analysis , Least-Squares Analysis , Fishes
5.
Molecules ; 27(17)2022 Aug 24.
Article in English | MEDLINE | ID: covidwho-2023941

ABSTRACT

Flavonoids are biologically active natural products of great interest for their potential applications in functional foods and pharmaceuticals. A hesperetin-7-O-glucoside inclusion complex with ß-cyclodextrin (HEPT7G/ßCD; SunActive® HCD) was formulated via the controlled enzymatic hydrolysis of hesperidin with naringinase enzyme. The conversion rate was nearly 98%, estimated using high-performance liquid chromatography analysis. The objective of this study was to investigate the stability, solubility, and spectroscopic features of the HEPT7G/ßCD inclusion complex using Fourier-transform infrared (FTIR), Raman, ultraviolet-visible absorption (UV-vis), 1H- and 13C- nuclear magnetic resonance (NMR), differential scanning calorimetry (DSC), liquid chromatography/mass spectroscopy (LC-MS), scanning electron microscopy (SEM), and powdered X-ray diffraction (PXRD) spectroscopic techniques including zeta potential, Job's plot, and phase solubility measurements. The effects of complexation on the profiles of supramolecular interactions in analytic features, especially the chemical shifts of ß-CD protons in the presence of the HEPT7G moiety, were evaluated. The stoichiometric ratio, stability, and solubility constants (binding affinity) describe the extent of complexation of a soluble complex in 1:1 stoichiometry that exhibits a greater affinity and fits better into the ß-CD inner cavity. The NMR spectroscopy results identified two different configurations of the HEPT7G moiety and revealed that the HEPT7G/ßCD inclusion complex has both -2S and -2R stereoisomers of hesperetin-7-O-glucoside possibly in the -2S/-2R epimeric ratio of 1/1.43 (i.e., -2S: 41.1% and -2R: 58.9%). The study indicated that encapsulation of the HEPT7G moiety in ß-CD is complete inclusion, wherein both ends of HEPT7G are included in the ß-CD inner hydrophobic cavity. The results showed that the water solubility and thermal stability of HEPT7G were apparently increased in the inclusion complex with ß-CD. This could potentially lead to increased bioavailability of HEPT7G and enhanced health benefits of this flavonoid.


Subject(s)
Hesperidin , beta-Cyclodextrins , Calorimetry, Differential Scanning , Flavonoids/chemistry , Glucosides , Protons , Solubility , Spectroscopy, Fourier Transform Infrared/methods , X-Ray Diffraction , beta-Cyclodextrins/chemistry
6.
J Pharm Biomed Anal ; 217: 114838, 2022 Aug 05.
Article in English | MEDLINE | ID: covidwho-1895252

ABSTRACT

Due to cultivation position, climate, harvest times, storage conditions and processing method, the evaluation of intra- and inter- batches quality consistency of botanical drugs has always been a thorny problem since it concerns safety and efficacy. The combination of fingerprint based on instrumental analysis and chemometrics is a common evaluation method in recent years. The differences between groups can be judged intuitively and superficially through principal component analysis (PCA) multi-dimensional score plots, but there is a lack of scientific and quantitative index to quantify the differences between groups. How to quantify the difference between groups is basically a blank area of research. Based on traditional F-statistic, we proposed a new F*-statistic to quantify the difference between groups in PCA score plots from the perspective of statistics. As the results revealed, the calculated F*-statistic was 2.58, smaller than the critical value 3.17 (α = 0.05), which indicated that there was no significant difference between groups. Our study add another dimension for PCA application, which offers a new strategy to quantify differences between groups by a new perspective, namely, a combination of fingerprint, chemometrics and statistics to evaluate inter-batches quality consistency quantitatively and objectively. Therefore, this manuscript could provide new ideas and technical references for the quality consistency evaluation of natural drugs, thus better guarantee their clinical efficacy and safety, and better promote industrial development.


Subject(s)
Drugs, Chinese Herbal , Chromatography, High Pressure Liquid/methods , Principal Component Analysis , Spectroscopy, Fourier Transform Infrared/methods
7.
Int J Mol Sci ; 23(7)2022 Apr 04.
Article in English | MEDLINE | ID: covidwho-1785743

ABSTRACT

This study aimed at obtaining hesperidin (Hed) and hesperetin (Het) systems with HP-ß-CD by means of the solvent evaporation method. The produced systems were identified using infrared spectroscopy (FT-IR), X-ray powder diffraction (XRPD), and differential scanning calorimetry (DSC). Moreover, in silico docking and molecular dynamics studies were performed to assess the most preferable site of interactions between tested compounds and HP-ß-CD. The changes of physicochemical properties (solubility, dissolution rate, and permeability) were determined chromatographically. The impact of modification on biological activity was tested in an antioxidant study as well as with regards to inhibition of enzymes important in pathogenesis of neurodegenerative diseases. The results indicated improvement in solubility over 1000 and 2000 times for Hed and Het, respectively. Permeability studies revealed that Hed has difficulties in crossing biological membranes, in contrast with Het, which can be considered to be well absorbed. The improved physicochemical properties influenced the biological activity in a positive manner by the increase in inhibitory activity on the DPPH radical and cholinoesterases. To conclude the use of HP-ß-CD as a carrier in the formation of an amorphous inclusion complex seems to be a promising approach to improve the biological activity and bioavailability of Hed and Het.


Subject(s)
Hesperidin , 2-Hydroxypropyl-beta-cyclodextrin/chemistry , Biological Availability , Calorimetry, Differential Scanning , Hesperidin/pharmacology , Solubility , Spectroscopy, Fourier Transform Infrared/methods , X-Ray Diffraction
8.
Sci Rep ; 12(1): 4269, 2022 03 11.
Article in English | MEDLINE | ID: covidwho-1740479

ABSTRACT

It has been reported that patients diagnosed with COVID-19 become critically ill primarily around the time of activation of the adaptive immune response. However the role of antibodies in the worsening of disease is not obvious. Higher titers of anti-spike immunoglobulin IgG1 associated with low fucosylation of the antibody Fc tail have been associated to excessive inflammatory response. In contrast it has been also reported that NP-, S-, RBD- specific IgA, IgG, and IgM are not associated with SARS-CoV-2 viral load, indicating that there is no obvious correlation between antibody response and viral antigen detection. In the present work the micro-Fourier-transform infrared reflectance spectroscopy (micro-FTIR) was employed to investigate blood serum samples of healthy and COVID-19-ill (mild or oligosymptomatic) individuals (82 healthcare workers volunteers in "Instituto de Infectologia Emilio Ribas", São Paulo, Brazil). The molecular-level-sensitive, multiplexing quantitative and qualitative FTIR data probed on 1 µL of dried biofluid was compared to signal-to-cutoff index of chemiluminescent immunoassays CLIA and ELISA (IgG antibodies against SARS-CoV-2). Our main result indicated that 1702-1785 [Formula: see text] spectral window (carbonyl C=O vibration) is a spectral marker of the degree of IgG glycosylation, allowing to probe distinctive sub-populations of COVID-19 patients, depending on their degree of severity. The specificity was 87.5 % while the detection rate of true positive was 100%. The computed area under the receiver operating curve was equivalent to CLIA, ELISA and other ATR-FTIR methods ([Formula: see text]). In summary, overall discrimination of healthy and COVID-19 individuals and severity prediction as well could be potentially implemented using micro-FTIR reflectance spectroscopy on blood serum samples. Considering the minimal and reagent-free sample preparation procedures combined to fast (few minutes) outcome of FTIR we can state that this technology is suitable for fast screening of immune response of individuals with COVID-19. It would be an important tool in prospective studies, helping investigate the physiology of the asymptomatic, oligosymptomatic, or severe individuals and measure the extension of infection dissemination in patients.


Subject(s)
COVID-19/metabolism , Immunoglobulin G/metabolism , SARS-CoV-2/immunology , Spectroscopy, Fourier Transform Infrared/methods , Adult , Antibodies, Viral/immunology , COVID-19/diagnostic imaging , COVID-19/immunology , COVID-19 Testing/methods , Enzyme-Linked Immunosorbent Assay , Female , Glycosylation , Humans , Luminescent Measurements , Male , Middle Aged , Patient Acuity , Reproducibility of Results , Sensitivity and Specificity , Spectroscopy, Fourier Transform Infrared/instrumentation , Viral Load
9.
Carbohydr Polym ; 280: 119006, 2022 Mar 15.
Article in English | MEDLINE | ID: covidwho-1588175

ABSTRACT

Caulerpa lentillifera (Bryopsidophyceae, Chlorophyta) is an edible seaweed attracting great attention for its expansion of farming scale and increasing consumption in these years. In the present study, a sulfated polysaccharide (CLSP-2) was isolated and separated from C. lentillifera, and its chemical structure was elucidated by a series of chemical and spectroscopic methods. Among these methods, mild acid hydrolysis and photocatalytic degradation were applied to release mono- and oligo-saccharide fragments which were further identified by HPLC-MSn analysis, affording the information of the sugar sequences and the sulfate substitution in CLSP-2. Results indicated that the backbone of CLSP-2 was constructed of →6)-ß-Manp-(1→ with sulfated branches at C2, which were comprised of prevalent →3)-ß-Galp4S-(1→, →3)-ß-Galp2,4S-(1→, and minor Xyl. In addition, the virus neutralization assay revealed that CLSP-2 could effectively protect HeLa cells against SARS-CoV-2 infection with an IC50 of 48.48 µg/mL. Hence, the present study suggests CLSP-2 as a promising agent against SARS-CoV-2.


Subject(s)
COVID-19/virology , Caulerpa/chemistry , Polysaccharides/chemistry , Polysaccharides/pharmacology , Antiviral Agents/chemistry , Antiviral Agents/pharmacology , Chromatography, High Pressure Liquid/methods , HeLa Cells , Humans , Hydrolysis , Magnetic Resonance Spectroscopy/methods , Mass Spectrometry/methods , Molecular Weight , Polysaccharides/analysis , SARS-CoV-2 , Seaweed/chemistry , Spectroscopy, Fourier Transform Infrared/methods , Sulfates/chemistry
10.
J Sep Sci ; 44(22): 4064-4081, 2021 Nov.
Article in English | MEDLINE | ID: covidwho-1525471

ABSTRACT

Coronil is a tri-herbal medicine consisting of immunomodulatory herbs, Withania somnifera, Tinospora cordifolia, and Ocimum sanctum. The formulation has been developed specifically as the supporting measure for COVID-19. Current investigation is aimed to identify the phytoconstituents in Coronil utilizing ultra-performance liquid chromatography-mass spectrometry coupled with quadrapole time of flight and to establish its quality standardization using high-performance liquid chromatography and high performance thin layer chromatography. Out of 52 identified compounds, cordifolioside A, magnoflorine, rosmarinic acid, palmatine, withanoside IV, withanoside V, withanone, betulinic acid, and ursolic acid were quantified in 15 different batches of Coronil on validated high-performance liquid chromatography method. Similarly, withanoside IV, withaferin A, magnoflorine, palmatine, rosmarinic acid, and ursolic acid were analyzed on high performance thin layer chromatography. Methods were validated as per the International Council for Harmonization guidelines. These methods were specific, reproducible, accurate, precise, linear (r2 > 0.99), and percent recoveries were within the prescribed limits. The content uniformity of Coronil was ascertained using Fourier transform infrared spectroscopy. Results indicated that, validated methods were fit for their intended use and the analytical quality of Coronil was consistent across the batches. Taken together, these developed methods could drive the analytical quality control of herbal medicines such as Coronil, and other formulations containing similar chemical profiles.


Subject(s)
COVID-19 Drug Treatment , Chromatography, High Pressure Liquid/methods , Herbal Medicine , Mass Spectrometry/methods , Phytochemicals/analysis , COVID-19/virology , Chromatography, Thin Layer/methods , Humans , Quality Control , SARS-CoV-2/isolation & purification , Spectroscopy, Fourier Transform Infrared/methods
11.
Sci Rep ; 11(1): 19980, 2021 10 07.
Article in English | MEDLINE | ID: covidwho-1462034

ABSTRACT

The coronavirus disease 2019 (COVID-19) is the latest biological hazard for the novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Even though numerous diagnostic tests for SARS-CoV-2 have been proposed, new diagnosis strategies are being developed, looking for less expensive methods to be used as screening. This study aimed to establish salivary vibrational modes analyzed by attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy to detect COVID-19 biological fingerprints that allow the discrimination between COVID-19 and healthy patients. Clinical dates, laboratories, and saliva samples of COVID-19 patients (N = 255) and healthy persons (N = 1209) were obtained and analyzed through ATR-FTIR spectroscopy. Then, a multivariate linear regression model (MLRM) was developed. The COVID-19 patients showed low SaO2, cough, dyspnea, headache, and fever principally. C-reactive protein, lactate dehydrogenase, fibrinogen, D-dimer, and ferritin were the most important altered laboratory blood tests, which were increased. In addition, changes in amide I and immunoglobulin regions were evidenced in the FTIR spectra analysis, and the MLRM showed clear discrimination between both groups. Specific salivary vibrational modes employing ATR-FTIR spectroscopy were established; moreover, the COVID-19 biological fingerprint in saliva was characterized, allowing the COVID-19 detection using an MLRM, which could be helpful for the development of new diagnostic devices.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , Saliva/chemistry , Spectroscopy, Fourier Transform Infrared/methods , Adult , Aged , Female , Humans , Immunoglobulins/analysis , Male , Middle Aged , Oxygen/analysis , SARS-CoV-2/isolation & purification
12.
Sci Rep ; 11(1): 15409, 2021 10 11.
Article in English | MEDLINE | ID: covidwho-1462018

ABSTRACT

Early diagnosis of COVID-19 in suspected patients is essential for contagion control and damage reduction strategies. We investigated the applicability of attenuated total reflection (ATR) Fourier transform infrared (FTIR) spectroscopy associated with machine learning in oropharyngeal swab suspension fluid to predict COVID-19 positive samples. The study included samples of 243 patients from two Brazilian States. Samples were transported by using different viral transport mediums (liquid 1 or 2). Clinical COVID-19 diagnosis was performed by the RT-PCR. We built a classification model based on partial least squares (PLS) associated with cosine k-nearest neighbours (KNN). Our analysis led to 84% and 87% sensitivity, 66% and 64% specificity, and 76.9% and 78.4% accuracy for samples of liquids 1 and 2, respectively. Based on this proof-of-concept study, we believe this method could offer a simple, label-free, cost-effective solution for high-throughput screening of suspect patients for COVID-19 in health care centres and emergency departments.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , Spectroscopy, Fourier Transform Infrared/methods , Adult , Aged , Brazil/epidemiology , COVID-19/epidemiology , Early Diagnosis , Female , Humans , Least-Squares Analysis , Machine Learning , Male , Middle Aged , Time Factors
13.
Int J Mol Sci ; 22(13)2021 Jul 01.
Article in English | MEDLINE | ID: covidwho-1304670

ABSTRACT

Silk fibroin (SF) has attracted much attention due to its high, tunable mechanical strength and excellent biocompatibility. Imparting the ability to respond to external stimuli can further enhance its scope of application. In order to imbue stimuli-responsive behavior in silk fibroin, we propose a new conjugated material, namely cationic SF (CSF) obtained by chemical modification of silk fibroin with ε-Poly-(L-lysine) (ε-PLL). This pH-responsive CSF hydrogel was prepared by enzymatic crosslinking using horseradish peroxidase and H2O2. Zeta potential measurements and SDS-PAGE gel electrophoresis show successful synthesis, with an increase in isoelectric point from 4.1 to 8.6. Fourier transform infrared (FTIR) and X-ray diffraction (XRD) results show that the modification does not affect the crystalline structure of SF. Most importantly, the synthesized CSF hydrogel has an excellent pH response. At 10 wt.% ε-PLL, a significant change in swelling with pH is observed. We further demonstrate that the hydrogel can be glucose-responsive by the addition of glucose oxidase (GOx). At high glucose concentration (400 mg/dL), the swelling of CSF/GOx hydrogel is as high as 345 ± 16%, while swelling in 200 mg/dL, 100 mg/dL and 0 mg/dL glucose solutions is 237 ± 12%, 163 ± 12% and 98 ± 15%, respectively. This shows the responsive swelling of CSF/GOx hydrogels to glucose, thus providing sufficient conditions for rapid drug release. Together with the versatility and biological properties of fibroin, such stimuli-responsive silk hydrogels have great potential in intelligent drug delivery, as soft matter substrates for enzymatic reactions and in other biomedical applications.


Subject(s)
Drug Delivery Systems/methods , Fibroins/chemistry , Glucose/metabolism , Hydrogels/chemical synthesis , Biocompatible Materials/chemistry , Drug Liberation , Fibroins/metabolism , Glucose/chemistry , Horseradish Peroxidase/chemistry , Hydrogen Peroxide/chemistry , Hydrogen-Ion Concentration , Polylysine/chemistry , Silk/chemistry , Spectroscopy, Fourier Transform Infrared/methods , X-Ray Diffraction
14.
Molecules ; 26(12)2021 Jun 10.
Article in English | MEDLINE | ID: covidwho-1282534

ABSTRACT

Multi-drug resistant pathogens are a rising danger for the future of mankind. Iodine (I2) is a centuries-old microbicide, but leads to skin discoloration, irritation, and uncontrolled iodine release. Plants rich in phytochemicals have a long history in basic health care. Aloe Vera Barbadensis Miller (AV) and Salvia officinalis L. (Sage) are effectively utilized against different ailments. Previously, we investigated the antimicrobial activities of smart triiodides and iodinated AV hybrids. In this work, we combined iodine with Sage extracts and pure AV gel with polyvinylpyrrolidone (PVP) as an encapsulating and stabilizing agent. Fourier transform infrared spectroscopy (FT-IR), Ultraviolet-visible spectroscopy (UV-Vis), Surface-Enhanced Raman Spectroscopy (SERS), microstructural analysis by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-Ray-Diffraction (XRD) analysis verified the composition of AV-PVP-Sage-I2. Antimicrobial properties were investigated by disc diffusion method against 10 reference microbial strains in comparison to gentamicin and nystatin. We impregnated surgical sutures with our biohybrid and tested their inhibitory effects. AV-PVP-Sage-I2 showed excellent to intermediate antimicrobial activity in discs and sutures. The iodine within the polymeric biomaterial AV-PVP-Sage-I2 and the synergistic action of the two plant extracts enhanced the microbial inhibition. Our compound has potential for use as an antifungal agent, disinfectant and coating material on sutures to prevent surgical site infections.


Subject(s)
Anti-Bacterial Agents/chemistry , Anti-Bacterial Agents/chemical synthesis , Aloe/chemistry , Antifungal Agents/chemistry , Gentamicins/chemistry , Microbial Sensitivity Tests , Microscopy, Electron, Scanning/methods , Nystatin/chemistry , Plant Extracts/chemistry , Povidone/chemistry , Salvia/chemistry , Salvia officinalis/chemistry , Spectrometry, X-Ray Emission/methods , Spectroscopy, Fourier Transform Infrared/methods , X-Ray Diffraction/methods
15.
Anal Chem ; 93(5): 2950-2958, 2021 02 09.
Article in English | MEDLINE | ID: covidwho-1041144

ABSTRACT

There is an urgent need for ultrarapid testing regimens to detect the severe acute respiratory syndrome coronavirus 2 [SARS-CoV-2] infections in real-time within seconds to stop its spread. Current testing approaches for this RNA virus focus primarily on diagnosis by RT-qPCR, which is time-consuming, costly, often inaccurate, and impractical for general population rollout due to the need for laboratory processing. The latency until the test result arrives with the patient has led to further virus spread. Furthermore, latest antigen rapid tests still require 15-30 min processing time and are challenging to handle. Despite increased polymerase chain reaction (PCR)-test and antigen-test efforts, the pandemic continues to evolve worldwide. Herein, we developed a superfast, reagent-free, and nondestructive approach of attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy with subsequent chemometric analysis toward the prescreening of virus-infected samples. Contrived saliva samples spiked with inactivated γ-irradiated COVID-19 virus particles at levels down to 1582 copies/mL generated infrared (IR) spectra with a good signal-to-noise ratio. Predominant virus spectral peaks are tentatively associated with nucleic acid bands, including RNA. At low copy numbers, the presence of a virus particle was found to be capable of modifying the IR spectral signature of saliva, again with discriminating wavenumbers primarily associated with RNA. Discrimination was also achievable following ATR-FTIR spectral analysis of swabs immersed in saliva variously spiked with virus. Next, we nested our test system in a clinical setting wherein participants were recruited to provide demographic details, symptoms, parallel RT-qPCR testing, and the acquisition of pharyngeal swabs for ATR-FTIR spectral analysis. Initial categorization of swab samples into negative versus positive COVID-19 infection was based on symptoms and PCR results (n = 111 negatives and 70 positives). Following training and validation (using n = 61 negatives and 20 positives) of a genetic algorithm-linear discriminant analysis (GA-LDA) algorithm, a blind sensitivity of 95% and specificity of 89% was achieved. This prompt approach generates results within 2 min and is applicable in areas with increased people traffic that require sudden test results such as airports, events, or gate controls.


Subject(s)
Algorithms , COVID-19/diagnosis , SARS-CoV-2/physiology , Spectroscopy, Fourier Transform Infrared/methods , Virion/chemistry , COVID-19/virology , Discriminant Analysis , Gamma Rays , Humans , Point-of-Care Testing , Principal Component Analysis , SARS-CoV-2/isolation & purification , Saliva/virology , Sensitivity and Specificity , Signal-To-Noise Ratio , Virion/radiation effects , Virus Inactivation
16.
Anal Chem ; 93(4): 2191-2199, 2021 02 02.
Article in English | MEDLINE | ID: covidwho-1019731

ABSTRACT

The outbreak of coronavirus disease 2019 (COVID-19) has led to substantial infections and mortality around the world. Fast screening and diagnosis are thus crucial for quick isolation and clinical intervention. In this work, we showed that attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FT-IR) can be a primary diagnostic tool for COVID-19 as a supplement to in-use techniques. It requires only a small volume (∼3 µL) of the serum sample and a shorter detection time (several minutes). The distinct spectral differences and the separability between normal control and COVID-19 were investigated using multivariate and statistical analysis. Results showed that ATR-FT-IR coupled with partial least squares discriminant analysis was effective to differentiate COVID-19 from normal controls and some common respiratory viral infections or inflammation, with the area under the receiver operating characteristic curve (AUROC) of 0.9561 (95% CI: 0.9071-0.9774). Several serum constituents including, but not just, antibodies and serum phospholipids could be reflected on the infrared spectra, serving as "chemical fingerprints" and accounting for good model performances.


Subject(s)
COVID-19/diagnosis , Spectroscopy, Fourier Transform Infrared/methods , Case-Control Studies , Diagnosis, Differential , Discriminant Analysis , Feasibility Studies , Humans
17.
Food Chem ; 353: 128718, 2021 Aug 15.
Article in English | MEDLINE | ID: covidwho-947222

ABSTRACT

Fraud in the food supply system will be exacerbated by shortages caused by climate change and COVID-19's impact. The dried herbs market exemplifies complex supply chains attractive to criminals seeking financial gain. Real-time remote testing is achievable through development of globally accessible chemometric models for portable near infrared devices, deployed throughout supply chains. This study describes building of models for detection of oregano adulteration, on portable near infrared devices, and comparison to a laboratory-based Fourier-Transform Infrared spectroscopy method. 33/34 portable devices were able to correctly classify 5 out of 6 samples successfully with all adulterated samples being correctly classified following the use of appropriate transferability pre-processing routines. The devices native setup shows limited ability to perform a true screening of oregano using the setup offered. However modifications to the setup could in the future offer a solution that facilitates fit-for-purpose real time detection of adulterated samples within the supply chain.


Subject(s)
Food Contamination/analysis , Origanum/chemistry , Laboratories , Spectroscopy, Fourier Transform Infrared/methods , Spectroscopy, Near-Infrared
SELECTION OF CITATIONS
SEARCH DETAIL